|
0-1-2
|
grib2 / codeflag / 4.2
|
Humidity mixing ratio
|
Humidity mixing ratio
|
stable
|
|
0-1-27
|
grib2 / codeflag / 4.2
|
Maximum relative humidity
|
Maximum relative humidity
|
stable
|
|
0-1-1
|
grib2 / codeflag / 4.2
|
Relative humidity
|
Relative humidity
|
stable
|
|
2-0-20
|
grib2 / codeflag / 4.2
|
Humidity parameter in canopy conductance
|
Humidity parameter in canopy conductance
|
stable
|
|
0-1-18
|
grib2 / codeflag / 4.2
|
Absolute humidity
|
Absolute humidity
|
stable
|
|
0-1-0
|
grib2 / codeflag / 4.2
|
Specific humidity
|
Specific humidity
|
stable
|
|
0-1-28
|
grib2 / codeflag / 4.2
|
Maximum absolute humidity
|
Maximum absolute humidity
|
stable
|
|
008
|
bufr4 / b / 13
|
Maximum relative humidity
|
|
stable
|
|
009
|
bufr4 / b / 13
|
Relative humidity
|
|
stable
|
|
003
|
bufr4 / b / 13
|
Relative humidity
|
|
stable
|
|
001
|
bufr4 / b / 13
|
Specific humidity
|
|
stable
|
|
2
|
bufr4 / codeflag / 0-02-024
|
Regression technique on 2 humidity values in layer
|
|
stable
|
|
1
|
bufr4 / codeflag / 0-02-024
|
Table with full range of humidity variation in layer
|
|
stable
|
|
5
|
bufr4 / codeflag / 0-08-001
|
Significant level, temperature and/or relative humidity
|
|
stable
|
|
18
|
bufr4 / codeflag / 0-08-040
|
Significant relative humidity level
|
|
stable
|
|
19
|
bufr4 / codeflag / 0-08-040
|
Relative humidity level selection terminated
|
|
stable
|
|
6
|
bufr4 / codeflag / 0-08-040
|
Begin missing relative humidity data
|
|
stable
|
|
11
|
bufr4 / codeflag / 0-08-040
|
End missing relative humidity data
|
|
stable
|
|
41
|
bufr4 / codeflag / 0-08-040
|
Significant relative humidity level (according to NCDC criteria)
|
|
stable
|
|
6
|
bufr4 / codeflag / 0-08-042
|
Significant humidity level
|
|
stable
|
|
6
|
bufr4 / codeflag / 0-08-086
|
Significant humidity level
|
|
stable
|
|
10
|
bufr4 / codeflag / 0-08-042
|
Beginning of missing humidity data
|
|
stable
|
|
11
|
bufr4 / codeflag / 0-08-042
|
End of missing humidity data
|
|
stable
|
|
7
|
bufr4 / codeflag / 0-08-083
|
Adjusted with respect to humidity
|
|
stable
|
|
6
|
bufr4 / codeflag / 0-33-005
|
Humidity data suspect
|
|
stable
|
|
3
|
bufr4 / codeflag / 0-33-026
|
Humidity element is wet
|
|
stable
|
|
4
|
bufr4 / codeflag / 0-33-026
|
Humidity element contaminated
|
|
stable
|
|
6
|
bufr4 / codeflag / 0-33-026
|
Heater fail and wet/contaminated humidity element
|
|
stable
|
|
024
|
bufr4 / b / 02
|
Integrated mean humidity computational method
|
|
stable
|
|
097
|
bufr4 / b / 02
|
Type of humidity sensor
|
|
stable
|
|
017
|
bufr4 / b / 02
|
Correction algorithms for humidity measurements
|
|
stable
|
|
170
|
bufr4 / b / 02
|
Aircraft humidity sensors
|
|
stable
|
|
007
|
bufr4 / b / 13
|
Minimum relative humidity
|
|
stable
|
|
251
|
wmdr / ObservedVariableAtmosphere
|
Humidity (at specified distance from reference surface)
|
|
superseded
|
|
143
|
wmdr / ObservingMethodAtmosphere
|
Raman lidar
|
Light detection and ranging (lidar) with Raman capability, ty...
|
stable
|
|
12249
|
wmdr / ObservedVariableAtmosphere
|
Relative humidity (with respect to water)
|
The ratio of the amount fraction of the water vapour in the a...
|
stable
|
|
12250
|
wmdr / ObservedVariableAtmosphere
|
Specific humidity
|
The ratio of the mass of water vapour in the air to the mass ...
|
stable
|
|
0-02-017
|
bufr4 / codeflag
|
Correction algorithms for humidity measurements
|
|
stable
|
|
0-02-024
|
bufr4 / codeflag
|
Integrated mean humidity computational method
|
|
stable
|
|
0-02-097
|
bufr4 / codeflag
|
Type of humidity sensor
|
|
stable
|
|
0-02-170
|
bufr4 / codeflag
|
Aircraft humidity sensors
|
|
stable
|